""" RaplPowerSource is a s-tui Source, used to gather power usage
information
"""

from __future__ import absolute_import

import time
import logging

from s_tui.sources.source import Source
from s_tui.sources.rapl_read import rapl_read

LOGGER = logging.getLogger(__name__)


class RaplPowerSource(Source):

    MICRO_JOULE_IN_JOULE = 1000000.0

    def __init__(self):
        Source.__init__(self)

        self.name = 'Power'
        self.measurement_unit = 'W'
        self.pallet = ('power light', 'power dark',
                       'power light smooth', 'power dark smooth')

        self.last_probe_time = time.time()
        self.last_probe = rapl_read()
        if not self.last_probe:
            self.is_available = False
            logging.debug("Power reading is not available")
            return
        self.max_power = 1
        self.last_measurement = [0] * len(self.last_probe)

        multi_sensors = []
        for item in self.last_probe:
            name = item.label
            sensor_count = multi_sensors.count(name)
            multi_sensors.append(name)
            name += "," + str(sensor_count)
            self.available_sensors.append(name)

    def update(self):
        if not self.is_available:
            return
        current_measurement_value = rapl_read()
        current_measurement_time = time.time()

        for m_idx, _ in enumerate(self.last_probe):
            joule_used = ((current_measurement_value[m_idx].current -
                           self.last_probe[m_idx].current) /
                          float(self.MICRO_JOULE_IN_JOULE))
            self.last_probe[m_idx] = joule_used

            seconds_passed = (current_measurement_time -
                              self.last_probe_time)
            logging.debug("seconds passed %s", seconds_passed)
            watts_used = float(joule_used) / float(seconds_passed)
            logging.debug("watts used %s", watts_used)
            logging.info("Joule_Used %d, seconds passed, %d", joule_used,
                         seconds_passed)

            if watts_used > 0:
                # The information on joules used elapses every once in a while,
                # this might lead to negative readings.
                # To prevent this, we keep the last value until the next update
                self.last_measurement[m_idx] = watts_used
                logging.info("Power reading elapsed")

        self.last_probe = current_measurement_value
        self.last_probe_time = current_measurement_time

    def get_maximum(self):
        return self.max_power

    def get_top(self):
        return 1